Water Analyzer For COD BOD

Pioneers in the industry, we offer cod bod monitor and bod cod tss ph analyzer online from India.

COD BOD Monitor

COD BOD Monitor
  • COD BOD Monitor
  • COD BOD Monitor
  • COD BOD Monitor
Get Best Quote
Approx. Price: Rs 10 Lakh / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
BrandATI USA
Usage/ApplicationUV-254 measurements are a practical indicator of dissolved organic compounds in water. Traditional m
MaterialUV LED
PhaseSingle Phase
COD measuring rangeUVA (0-1.3 ABS), UVT (0-100%) and SUVA Surrogate measurements DOC,TOC, BOD, COD Turbidity, 0-4000 NT
BOD Measuring RangeUVA (0-1.3 ABS), UVT (0-100%) and SUVA Surrogate measurements DOC,TOC, BOD, COD Turbidity, 0-4000 NT
TSS measuring rangeUVA (0-1.3 ABS), UVT (0-100%) and SUVA Surrogate measurements DOC,TOC, BOD, COD Turbidity, 0-4000 NT
Warm Up Time2 mins
Maintenance Cycle1 year
Measurement PrincipleUVA (0-1.3 ABS), UVT (0-100%) and SUVA Surrogate measurements DOC,TOC, BOD, COD Turbidity, 0-4000 NT

Features & specification

UV-254 and Turbidity Measurement in one sensor Water quality monitoring continues to grow in importance as water sources come under increasing pressure. Conventional measurements of turbidity, pH, conductivity, and color provide useful information but do not reflect changes in dissolved organic constituents. Many of these dissolved organic compounds absorb UV energy. A UV-254 absorption measurement has increasingly become a useful indicator of organic carbon content, providing operators with real-time information on contaminant levels. 0 20 40 60 80 100 120 1.400 1.200 1.000 0.800 0.600 0.400 0.200 0.000 DOC (mg/l KHP) U V A ATI’s Model Q46UV Monitor continuously monitors the quality of raw water, treated water, recycle water, or wastewater effluents. With a relatively long 20 mm absorption path length, this sensor provides excellent sensitivity to small changes in Dissolved Organic Carbon (DOC). Employing a pulsed UV LED light source and scratch resistant sapphire optical windows, the UV-254 sensor will provide years of trouble-free monitoring. UV ABSORPTION & TURBIDITY IN A SINGLE SENSOR • Long life Pulsed UV LED for extended service life. • 20 mm measurement path for high sensitivity • 860 nm IR turbidity measurement (ISO-7027) • IR sensor measures both 90° scatter and absorption • Analog outputs for both UVA and Turbidity • Available 3rd output for DOC • User editable table for UVA vs DOC/TOC/COD/BOD • Chemical cleaning system option • Automatic Sensor Fouling Compensation

  • AC or DC Power Option
  • Extra Outputs
  • Range Flexibility
  • Analog Output Options
  • PID Output
  • Digital Communications for Profibus-DP, Modbus-RTU, Modbus-TCP/IP or Ethernet-IP.
  •  Relay Contacts Options
  • Flexible Mounting Options
  • Large, Back-lit LCD Display
  • Sensor Diagnostics
Request
Callback


Additional Information:

  • Item Code: Q46UV
  • Production Capacity: 100000
  • Delivery Time: 6-8 weeks
Yes! I am Interested

Bod Cod Tss Ph Analyzer Online

Bod Cod Tss Ph Analyzer Online
  • Bod Cod Tss Ph Analyzer Online
  • Bod Cod Tss Ph Analyzer Online
  • Bod Cod Tss Ph Analyzer Online
  • Bod Cod Tss Ph Analyzer Online
Get Best Quote
Approx. Price: Rs 5 Lakh / PieceGet Latest Price
Product Brochure
Features & specifications
  • F
  • This industrial online controller is a new intelligent controller with high
  • intelligence and flexibility, which can measure COD,BOD, TSS, TOC water
  • quality parameters and water temperature at the same time, and is widely
  • used in aquaculture, municipal sewage treatment plants, electric power, water
  • supply, pharmaceutical, chemical, food and other industries.
  • 1. Large screen display interface, eye-catching and convenient
  • 2. With digital communication function, can be connected to the upper
  • computer, communication using isolation technology, strong anti-interference
  • ability
  • 3. With relay alarm setting function, the amount of hysteresis can be freely
  • adjusted to avoid frequent relay on and off
  • 4. Password management function to prevent misoperation of
  • non-professional personnel
  • 5. Menu prompt function, convenient for users to operate
  • 6. 4-20mA current output function is optional when purchasing, which is
  • convenient for control center to collect data.
  • Technical parameters of the instrument:
  • Measurement range:
  • COD (0 ~ 10000 mg/L equiv. KHP);
  • BOD:0~3500 mg/L
  • TSS: 0 ~ 1000 mg/L
  • TOC: 1.5 ~ 1100 mg/l equiv KH
  • Accuracy: ±5%
  • Resolution: 0.01mg/L
  • Signal output: RS485 isolated protection output. (Optional 4-20mA current
  • output function is available.)
  • Alarm output: normally open contact relay (3A/250VAC)
  • Power supply: AC 220V
  • Power consumption: 3W
  • Environmental conditions: (1) temperature 0 ~ 60 ℃ (2) humidity ≤ 85% RH
  • Overall dimensions: 144 × 144 × 115mm (H × W × D)
  • Opening size: 138 × 138mm (H × W)
  • II. Combination and installation
  • 2.1 Host fixing
  • The transmitter can be installed in panel or wall mount.
  • 2.2 Plate mounting reference diagram
  • Electrode installation method
  • Installation:
  • Please check the appearance of the cable for damage before installation
  • operation, and spread out the cable.
  • 1. Input type sensor should be used to avoid the sensor hitting the wall or
  • other facilities due to water flow, if the water flow rate is too fast need to fix the
  • sensor.
  • 2. There should not be any obstructions in front of the measurement, such as
  • fluorometric sensors should avoid light exposure.
  • 3. The installation of the sensor should not exceed the water depth position
  • from the horizontal 2 meters, and according to the water flow fluctuations, the
  • installation position should not be less than 30 cm water depth. (According to
  • the measured water body can be adjusted)
  • 4. The sensor should be installed in the location without air bubbles, to
  • prevent the impact of air bubbles on the sensor measurement data.
Request
Callback


Additional Information:

  • Item Code: 1
  • Minimum Order Quantity: 1 Piece
  • Production Capacity: 100000
  • Delivery Time: 2-3 weeks
  • Packaging Details: Our controllers do not require any maintenance under normal conditions, but the electrodes need to be cleaned and calibrated regularly to ensure accurate and stable measurement values and to keep the system operating properly. Please refer to the electrode manual for electrode maintenance.